2026年06月19日 11:55:44 来源:广东宏拓仪器科技有限公司 >> 进入该公司展台 阅读量:19
PAGE | CODE | VALUE | COMENTS | ||
dF Measurements Settings | diSP Renewal Frequency of density | 0 | STABLE | ||
1 | UNSTABLE | ||||
Err Decimal places which contain calculative tolerance | 0 | Tolerance decimal places Shown and Still | |||
1 | Tolerance more than ±2 Flashing | ||||
2 | Tolerance more than ±2 Deleted | ||||
AL-t Set Measuring time in Air/Water | 0 | 0.0 Sec/0.0 Sec ※Press key, and get a result immediately. | |||
1 | 0.0 Sec/1.8 Sec | ||||
2 | 1.8 Sec/4.2 Sec | ||||
3 | 4.2 Sec/7.8 Sec | ||||
4 | 7.8 Sec/16.2 Sec | ||||
Lqd Setting Density of a liquid Mediuim | 0 | Prohibited | |||
1 | Permitted | ||||
dAtA Data Output (in auto-printing) | 0 | Output aerial Weight and Density | |||
1 | Output collectively aerial Weight, underwater Weight, Density and Volume | ||||
Func Balance and Output settings | Poff Auto power-off | 0 | OFF | ||
1 | ON | ||||
St-b Stability indication range | 0 | Stable mark appears within ±0.5g per 0.5 Sec | |||
1 | Stable mark appears within ±1.0g per 0.5 Sec | ||||
2 | Stable mark appears within ±2.0g per 0.5 Sec | ||||
trc Zero trucking | 0 | OFF | |||
1 | ON | ||||
CP Comparator Mode | 0 | OFF | |||
1 | ON | ||||
bEP Buzzer sound ※Optional kit needed | ― | ― | |||
― | ― | ||||
― | ― | ||||
Prt Data output Mode | 0 | Command mode/ Stream mode(Output the same data repeatedly) | |||
1 | Command mode/ B key mode | ||||
2 | Command mode/ Auto-printing after finishing measurement | ||||
PUSE Output data interval | 0 | No interval( Set this when sending data to a computer) | |||
1 | 1.6 sec interval | ||||
2 | 3.2 sec interval (Set this when using Printer: 8121B) | ||||
inFo GLP Output Format | 0 | OFF | |||
1 | Output data when using Printer: 8121B | ||||
2 | Output data when using general-purpose computer | ||||
bPS Baud Rate | 0 | 2400bps | |||
1 | 4800bps | ||||
2 | 9600bps | ||||
btPr Data bit / Parity bit | 0 | 7bit EVEN | |||
1 | 7bit ODD | ||||
2 | 7bit NON | ||||
LtUP Display's Backlight | 0 | Always OFF | |||
1 | Turn off in 3 seconds after stable mark appears | ||||
2 | Turn off in 10 seconds after stable mark appears | ||||
3 | Turn off in 30 seconds after stable mark appears | ||||
4 | Turn off in 60 seconds after stable mark appears | ||||
5 | Always ON | ||||
oP d Optional Setting | R1 A R1 b R2 A R2 b R3 A R3 b | R1 | Optional Set a specific Gravity of main metal | ||
R1 | Optional Set a specific Gravity of alloyed metal | ||||
R2 | Optional NO.2 Set a specific Gravity of main metal | ||||
R2 | Optional NO.2 Set a specific Gravity of alloyed metal | ||||
R3 | Optional NO.3 Set a specific Gravity of main metal | ||||
R3 | Optional NO.3 Set a specific Gravity of alloyed metal | ||||
CP Hi | Comparator Max Density | ||||
CP Lo | Comparator Min Density | 出荷時設定000000となっています | |||
id | Setting GLP output ID number | ||||